ACE-031 is a decoy receptor construct built from the extracellular ligand-binding domain of activin receptor type IIB fused to an immunoglobulin Fc region. It works on the myostatin pathway from the opposite direction to a binding protein: rather than wrapping the ligand, it presents a soluble copy of the receptor those ligands are trying to reach, intercepting them before they contact the membrane-bound receptor.
- Product Name: ACE-031
- Catalogue Number: ACE1-024
- Unit Size: Multiple vial sizes available
- Other Names: Ramatercept, ActRIIB-Fc
- Form: Lyophilized solid
ACE-031 has been characterized in published preclinical and clinical work documenting increases in lean mass in animal models and in early human study cohorts. Because activin receptor type IIB binds several ligands beyond myostatin, including activins and other growth differentiation factors, the published record also documents effects attributable to that broader interception, which became a defining feature of its development history.
What Is ACE-031
ACE-031 is a fusion protein, not a peptide, supplied as a lyophilized solid for laboratory research. The Fc portion serves two purposes: it dimerizes the construct so that it presents two ligand-binding domains, matching the dimeric ligands it intercepts, and it confers the extended circulating half-life characteristic of antibody-derived molecules.
Mechanism of Action: How Does ACE-031 Work
ACE-031 presents the same extracellular domain that the membrane-bound receptor uses to capture its ligands. Circulating myostatin, activins and related growth differentiation factors bind it with comparable affinity to the real receptor and are thereby removed from the pool available to signal. Because the sequestered ligand never reaches the membrane, the type I receptor is never recruited, SMAD2/3 are not phosphorylated, and the suppressive transcriptional program those factors drive does not run. The breadth of interception is intrinsic to the design: a decoy receptor cannot be more selective than the receptor it copies.
- Soluble ActRIIB domain → ligand interception before membrane contact
- Fc dimerization → two binding domains matching dimeric ligands
- Reduced receptor engagement → SMAD2/3 phosphorylation suppressed
- Multi-ligand binding → activins and other GDFs intercepted alongside myostatin
- Fc domain → extended circulating half-life
Core Areas of Scientific Investigation
- Decoy Receptor Pharmacology: ACE-031 is a model construct for studying ligand trapping by receptor mimicry rather than by binding protein.
- Ligand Selectivity: its multi-ligand binding makes it the reference tool for studying the consequences of intercepting a receptor’s entire ligand set.
- Fc Fusion Design: investigators study dimerization and half-life extension conferred by the immunoglobulin portion.
- Comparative Pathway Inhibition: paired against follistatin, it separates receptor-level from ligand-level interception.
ACE-031 Dosage in Published Research
Doses reported in the published literature are expressed in milligrams per kilogram administered subcutaneously in animal and human study cohorts, with dosing intervals of several weeks reflecting the extended half-life conferred by the Fc domain. Figures vary by study and should be read from the individual publications. These are published parameters of completed experiments. They are not a recommendation, and no administration protocol is supplied with this product.
Adverse Events Reported in the Literature
Published study cohorts record epistaxis, telangiectasia and gum bleeding, effects attributed to interception of ligands beyond myostatin that participate in vascular regulation. These findings informed the discontinuation of its clinical development and are reported here as documented literature, not as safety guidance for this product.
Usage, Reconstitution and Storage
Supplied as a lyophilized solid to preserve stability during transport and storage. As a large fusion protein it is particularly sensitive to repeated freeze-thaw cycling, to agitation, and to surface adsorption at low concentrations; low-binding labware and gentle reconstitution without vortexing are advisable.
Pure Peptides recommends bacteriostatic water as the reconstitution solvent, and that both the lyophilized material and the chosen solvent be allowed to reach ambient laboratory temperature before reconstitution. This helps maintain structural integrity during dissolution. Reconstitution solutions and a peptide storage case are supplied separately.
Legal and Safety Information
All Pure Peptides products, including ACE-031, are sold exclusively for scientific and research purposes. This product is a laboratory reference standard for in vitro and animal research applications. It is not a dietary supplement, medical food, cosmetic, or drug. It has not been evaluated by the Food and Drug Administration (FDA) and is not approved for therapeutic, diagnostic, or recreational human consumption. Enquiries regarding human consumption cannot be answered. Any use outside an authorized laboratory environment is strictly prohibited.
Technical Data
| Identification | |
| Molecular Class | ActRIIB extracellular domain / IgG Fc fusion protein |
| Physical and Chemical Properties | |
| Physical Appearance | White lyophilized solid |
| Form | Sterile filtered white lyophilized (freeze-dried) |
| Solubility | Aqueous soluble |
| Recommended Solvent | Bacteriostatic water; reconstitute gently, do not vortex |
| Analytical and Quality Control | |
| Purity % | 95% |
| Research Use and Safety | |
| Caution | Research use only / Not for human or veterinary use |
| Storage, Handling and Stability | |
| Storage Temperature (lyophilized) | Store desiccated below −18°C |
| Storage Temperature (reconstituted) | Store at 4°C for short-term use; below −18°C for future use |
| Light Sensitivity | Protect from light |
Why Choose Pure Peptides Reference Compounds
When executing high-level metabolic research, compounding variables can compromise data integrity. We isolate and eliminate those variables.
- Verified High Purity: every batch is analyzed by high-performance liquid chromatography, with the purity profile recorded against the lot.
- Structural Stability: the synthesis protocol yields stable chains that resist premature degradation under the recommended storage conditions.
- Temperature-Shielded Logistics: shipped in insulated packaging to preserve structural integrity in transit to the receiving laboratory.
- Full Batch Traceability: lot number and manufacture date are recorded for every vial.
Suggested Research Combinations
- GDF-8 (Myostatin) — the principal ligand this construct intercepts, required for binding and competition assays.
- Follistatin 344 — a ligand-binding glycoprotein acting on the same pathway by encirclement rather than receptor mimicry.
- IGF-1 LR3 — a growth factor on the opposing anabolic pathway, studied in parallel in muscle regulatory designs.
Frequently Asked Questions
How does a decoy receptor differ from a binding protein?
A binding protein wraps the ligand directly. A decoy receptor presents a soluble copy of the receptor the ligand is seeking, intercepting it before it reaches the membrane. The endpoint is similar; the mechanism and selectivity profile differ.
Why does it bind more than myostatin?
Because activin receptor type IIB itself binds several ligands, including activins and other growth differentiation factors. A decoy receptor cannot be more selective than the receptor it copies, so the breadth is intrinsic to the design.
What does the Fc portion do?
Two things. It dimerizes the construct so it presents two ligand-binding domains, matching the dimeric ligands it intercepts, and it confers the extended circulating half-life characteristic of antibody-derived molecules.
How should this protein be stored?
The sealed lyophilized vial should be stored desiccated below minus 18 degrees Celsius. As a large fusion protein it is sensitive to agitation and surface adsorption, so gentle reconstitution without vortexing and low-binding labware are advisable.
Is this product approved for human use?
No. This material is a laboratory reference standard supplied strictly for in vitro and preclinical research. It has not been evaluated by the Food and Drug Administration and is not approved for therapeutic, diagnostic, or human application of any kind.
Regulatory Status
ACE-031 is supplied strictly for in vitro and preclinical research purposes. Its use is considered experimental; long-term safety and efficacy in humans have not been established. All referenced findings derive from published preclinical and clinical research, and results in one model may not translate to another.


Reviews
There are no reviews yet.